Print Back
Operation
Utilizing proven FlareGrip® technology, the Dual Containment Flare Fitting (DCF) transforms standard FlareGrip fittings to PFA/FEP over PFA dual containment fittings. This ensures true dual containment throughout the chemical delivery system. The DCF can mate with chemical delivery systems, wet tools, valve boxes, individual components, and drain lines.
Unit of Measure

Specifications

Dimension A

2.25 in

Dimension B

2.46 in

Dimension C

1.5 in

Dimension D

1.29 in

Dimension E

1.50 in

Body Fitting

1/4" Flare x 1/2" Flare

DCF Adapter

High Purity PFA

Inner Wetted Line

High Purity PFA

Panel Cutout Diameter

1.02 in

Maximum Temperature

130 ºC

Maximum Operating Pressure at Ambient Temperature

150 psig

Outer Containment Line

FEP PFA

Flare Grip Nut

ETFE

Applications

Applications

The Rear Seal Bulkhead version would be utilized primarily in applications that require sealing on the internal surface of the containment area such as a process tool cabinet. It can also be used as a pass through device which will terminate the outer containment on the face of bulkhead while allowing the primary process line to pass through a bulkhead uninterrupted. The PFA/FEP over PFA construction allows maximum personal safety, performance and environmental protection in any media application and is ideal for compliance with state and local environmental legislation.

Features/Benefits

Features/Benefits

  • Chemically inert, all high purity PFA wetted parts
  • ConvoFlex™ FEP/PFA tubing as secondary containment
  • Annular space may be used for media temperature control
  • Primary containment pressure up to 150 PSIG at ambient

Notes

Notes

  • Consult factory for Kalrez O-ring option and more information